Weight sensor TRC series

We have 2 type of TRC series.

The difference is the weight sensor has Built-in mechanical stopper or not.

・With Built-in mechanical stopper
=TRC-xxx-xxx-CO

・Without Built-in mechanical stopper
=TRC-xxx-xxx-CO

Model Rated Weight Size A Size B Thickness
TRC-030-200-CO 300N 200 190 17mm
TRC-030-250-CO 250 240
TRC-050-200-CO 500N 200 190
TRC-050-250-CO 250 240

 

Specification

Model TRCーロロロ ロロロ CO / TRCーロロロ ロロロ CO
Rated Weight 300N (=:: 30Kg)、500N (=:: 50Kg)
Output 4-20mA
Non-linearity 5%R. 0.
Hysteresis 5%R. 0.
Allowable overload 120%R. C.
Marginal overload 150%R. C.
Power-supply voltage 24V DC士10%
Operating ambient temperature 0-50℃
Cable Φ5 3 Core Cable 2m
Color of Cable Red: INPUT (DC24V)
White: OUTPUT (4mA~20mA)
Black: GND (Common power supply and output)
Materials Stainless steel (upper plate, lower plate), PET (seal)
Other With Built-in mechanical stopper

Attention 1:
Since the zero and gain trimmers are adjusted at the time of shipment, do not operate them except during calibration.

Level management is completed with one unit / Current output 4 to 20 mA / Low cost level sensor

 
 
 
 
 
 
 
 
 
 
 
 
 

What is the difference between a weight sensor and an electronic balance? 17196 views

Electronic balances are highly accurate, lightweight, and suitable for measuring masses with a ratin

Please tell me how to install the weight sensor. 17131 views

TTS series, and LTS series are manufactured to the desired specifications, so tapping holes for fixi

Is it possible to tare? What should I do? 17103 views

You can tare from the amplifier display. For the MX-11 series, if you press and hold the leftmost ZE

Is there anything I should be careful about when handling and installing? 15365 views

The weight sensor is said to be able to apply a load of 100,000 times. Although it has a very long l

There is something wrong with the zero point. It moves every time it measures. 15350 views

There may be a problem with the load cell of the internal element. If a load exceeding the rated wei

No longer displays the exact weight. 15292 views

Please refer to the troubleshooting in the specifications or contact our staff. Frequently asked que

I want to know the measurement principle of weight sensors and load cells. 13822 views

Our weight sensor and load cell use a strain gauge for measurement. The resistance foil is attached

Is the environment in which it can be installed limited? 14033 views

Due to its intended use, weight sensors are often used in clean rooms or indoors. The temperature ra

Does the shape change when a load is applied? 14021 views

Although it depends on the sensor accuracy, the shape of the sensor sinks up to several mm when a ra

Can it be used only with the weight sensor and load cell? 14009 views

The output of the weight sensor is a weak voltage of several mV / V. Since it is necessary to amplif

What should I get the output from the sensor? 13070 views

The output from our weight sensor and load cell is several mv / v (at rated time). By using it as a